HLS Healthcare


Vivid Vision

Rise stand up lift: compact,
quick and comfortable

The Rise active patient lift is designed with the user in mind.Its very compact base makes the lift very manoeuvrable and particularly well-suited for use in small spaces. Due to the short footplate, the Rise can be positioned close to the patient, bringing the handles within easy reach. Finally the swift and easy-to-follow lifting speed and the leg rest with memory foam top layer guarantee a comfortable lifting experience for all.

The Rise is standard equipped with an internal NiMH battery with charger. The very large capacity of the battery ensures that the lift is always ready for use.

The patented esense drive system makes it possible to move the lift with minimal force in any direction. A force sensor in the handlebar feels how the lift is pushed and translates this to the right direction and speed of the electric wheel under the lift. The low operating forces prevent physical complaints caused by pushing and pulling. The intuitive control guarantees a minimal learning time. Additionally esense patient lifts are standard equipped with Ergo feedback to alert the user when too much force is used to move the lift. The live feedback helps users to work within the ergonomic guidelines and thus contributes directly to prevent physical overload.

Esense Rise

SpecificationsRise
Weight capacity180 kg
Length of base (frame)90 cm
Height of base11,5 cm
Maximum width frame - closed legs64,5 cm
Maximum internal width frame - open legs84,5 cm
Vertical range75 cm
Protection gradeIPX2
Battery typeNiMH
Protection gradeIPX2
Battery typeNiMH
Battery voltage and capacity*24V 9Ah
Average number of transfers on a full battery**75
Guaranteed battery lifetime in charge cycles500 x

* The Rise is also available in a manual version without esense drive system. This version is equipped with a lower capacity battery.
** Calculation available upon request.

How to use esense Rise active patient lift

Features

Esense rise handlebar with force sensors Esense Rise | Active patient lift
Handlebar with force sensors
esense rise leg rest Esense Rise | Active patient lift
Leg Rest

Learn More About Available Options

For further information or to discuss available options, please feel free to get in touch with the HLS Healthcare team by calling 1300 931 893 or filling out the contact form below. Our product specialists will be more than happy to assist you.

Contact Us

HLS Healthcare

HLS Healthcare esense line

esense europian model hls healthcare m Esense Rise | Active patient lift

HLS Healthcare

esense ergomeasurement

Ergometer Esense Rise | Active patient lift

Report Example

ergomeasurement example report 1 m Esense Rise | Active patient lift

The highest measured force was 34 kg.

ergomeasurement example report 2 Esense Rise | Active patient lift
  • During the test at 15 moments too much force was used. This is converted to 6 times every 5 minutes. Each time is really once too often.
  • When the force is above 15 kg, the arms are pushing and pulling in reverse direction in 51% of time. This also increases the risk of physical complaints for forces under 20 kg.
ergomeasurement example report 3 Esense Rise | Active patient lift

During the test 3 users excersised a force over 20 kg. The user that passed this limit most often, did so 6 times.

ergomeasurement example report 4 Esense Rise | Active patient lift

Related Articles

Learn more about the Esense

Esense ‘makes sense’ when it comes to reducing push-pull stress

Healthcare product designers are constantly coming up with new and better ways of doing things

Push that floor hoist! Pull that trolley! How much force is too much?

In healthcare we are constantly assessing ourselves. We ask ourselves questions about what we do

  1300 931 893

Get in Touch with Us

To arrange a product demonstration of any products from the HLS Healthcare product range, please call now or complete the form below. One of our product specialists will be more than happy to discuss your project requirements.

  • This field is for validation purposes and should be left unchanged.